TY - GEN
T1 - A real-time realization of an automatic dynamic range adjustment method on a smart mobile device for point-of-care ultrasound imaging
AU - Kim, Jee Hoo
AU - Lee, Yeonhwa
AU - Kang, Jinbum
AU - Yoo, Yangmo
N1 - Publisher Copyright:
© 2014 IEEE.
PY - 2014/10/20
Y1 - 2014/10/20
N2 - Dynamic range (DR) is one of the most essential parameters that determine the image quality and feature representation in ultrasound B-mode imaging. Thus, the automatic DR adjustment (ADRA) method was previously proposed for reducing user dependency and improving image quality. In this paper, for a smart phone based point-of-care ultrasound imaging system, the real-time realization of the ADRA method on a smart phone using a mobile GPU is presented. The ADRA method was implemented on the NEXUS 4 running on the Android 4.3 by utilizing the several graphics pipelines supported from the OpenGL ES platform. For evaluating the real-time ADRA method, 200 frames of in vivo abdominal data were acquired by a 3.5-MHz convex array transducer from with a commercial ultrasound scanner equipped with a research package (Accuvix V10, Samsung Medison, Seoul, Korea). The GPU-based ADRA method showed the enhanced contrast-to-noise ratio (CNR) compared to the conventional method with a fixed DR value, i.e., 3.89±0.71 vs. 3.35±0.88, respectively. In addition, it showed a higher frame rate (i.e., >60 frames/sec) compared to the CPU-based ADRA method while providing the comparable CNR value. These results indicate that the ADRA method can be successfully supported in the smartphone while improving the image quality with less user dependency.
AB - Dynamic range (DR) is one of the most essential parameters that determine the image quality and feature representation in ultrasound B-mode imaging. Thus, the automatic DR adjustment (ADRA) method was previously proposed for reducing user dependency and improving image quality. In this paper, for a smart phone based point-of-care ultrasound imaging system, the real-time realization of the ADRA method on a smart phone using a mobile GPU is presented. The ADRA method was implemented on the NEXUS 4 running on the Android 4.3 by utilizing the several graphics pipelines supported from the OpenGL ES platform. For evaluating the real-time ADRA method, 200 frames of in vivo abdominal data were acquired by a 3.5-MHz convex array transducer from with a commercial ultrasound scanner equipped with a research package (Accuvix V10, Samsung Medison, Seoul, Korea). The GPU-based ADRA method showed the enhanced contrast-to-noise ratio (CNR) compared to the conventional method with a fixed DR value, i.e., 3.89±0.71 vs. 3.35±0.88, respectively. In addition, it showed a higher frame rate (i.e., >60 frames/sec) compared to the CPU-based ADRA method while providing the comparable CNR value. These results indicate that the ADRA method can be successfully supported in the smartphone while improving the image quality with less user dependency.
KW - Automatic Dynamic Range Adjustment
KW - Automatic Image Optimization
KW - Dynamic range
KW - Point-of-Care Ultrasound
UR - https://www.scopus.com/pages/publications/84910091429
U2 - 10.1109/ULTSYM.2014.0303
DO - 10.1109/ULTSYM.2014.0303
M3 - Conference contribution
AN - SCOPUS:84910091429
T3 - IEEE International Ultrasonics Symposium, IUS
SP - 1229
EP - 1232
BT - IEEE International Ultrasonics Symposium, IUS
PB - IEEE Computer Society
T2 - 2014 IEEE International Ultrasonics Symposium, IUS 2014
Y2 - 3 September 2014 through 6 September 2014
ER -