TY - JOUR
T1 - A Study on sEMG-Based Motor Variability and Functional Connectivity of the Upper Limb Depending on Weight Distributions in a Handle of a Cordless Stick-Type Vacuum Cleaner
AU - Yu, Hayeon
AU - Kang, Eunchae
AU - Chang, Joonho
N1 - Publisher Copyright:
© 2022 by the authors. Licensee MDPI, Basel, Switzerland.
PY - 2022/7/1
Y1 - 2022/7/1
N2 - This study investigated the muscle activities, motor variability, and functional connectivity of the upper limb as a function of weight distributions in a handle of a cordless stick-type vacuum cleaner. Eighteen female college students with experience of vacuum cleaner-use participated in testing. Five handles with different centers of mass (CM) were prepared (centroid, top-rear, top-front, bottom-front, and bottom-rear), and electromyography for the muscles of the upper limb were measured during vacuuming. The results showed that the %MVC values of the Extensor Carpi Ulnaris (p = 0.0038) and Deltoid Middle (p = 0.0094) increased but that of the Biceps Brachii (p = 0.0001) decreased, as the CM moved from the top to bottom area of the handle. The motor variability of the Extensor Carpi Ulnaris (p = 0.0335) and Brachioradialis (p = 0.0394) significantly varied depending on the CM locations but failed to show significance in the post-hoc analyses. Lastly, the functional connectivity values of the muscle pairs such as the Extensor Carpi Ulnaris–Deltoid Middle (p = 0.0016), Extensor Carpi Ulnaris–Upper Trapezius (p = 0.0174), Brachioradialis–Biceps Brachii (p = 0.0356), and Biceps Brachii–Upper Trapezius (p = 0.0102) were significantly altered as a function of the CM locations. The lowest functional connectivity was found with the handle of which CM was at centroid.
AB - This study investigated the muscle activities, motor variability, and functional connectivity of the upper limb as a function of weight distributions in a handle of a cordless stick-type vacuum cleaner. Eighteen female college students with experience of vacuum cleaner-use participated in testing. Five handles with different centers of mass (CM) were prepared (centroid, top-rear, top-front, bottom-front, and bottom-rear), and electromyography for the muscles of the upper limb were measured during vacuuming. The results showed that the %MVC values of the Extensor Carpi Ulnaris (p = 0.0038) and Deltoid Middle (p = 0.0094) increased but that of the Biceps Brachii (p = 0.0001) decreased, as the CM moved from the top to bottom area of the handle. The motor variability of the Extensor Carpi Ulnaris (p = 0.0335) and Brachioradialis (p = 0.0394) significantly varied depending on the CM locations but failed to show significance in the post-hoc analyses. Lastly, the functional connectivity values of the muscle pairs such as the Extensor Carpi Ulnaris–Deltoid Middle (p = 0.0016), Extensor Carpi Ulnaris–Upper Trapezius (p = 0.0174), Brachioradialis–Biceps Brachii (p = 0.0356), and Biceps Brachii–Upper Trapezius (p = 0.0102) were significantly altered as a function of the CM locations. The lowest functional connectivity was found with the handle of which CM was at centroid.
KW - center of mass of a handle
KW - cordless stick-type vacuum cleaner
KW - EMG analysis
KW - functional connectivity
KW - motor variability
UR - http://www.scopus.com/inward/record.url?scp=85132828286&partnerID=8YFLogxK
U2 - 10.3390/s22134835
DO - 10.3390/s22134835
M3 - Article
C2 - 35808335
AN - SCOPUS:85132828286
SN - 1424-3210
VL - 22
JO - Sensors
JF - Sensors
IS - 13
M1 - 4835
ER -