Skip to main navigation Skip to search Skip to main content

Automated Segmentation of MRI White Matter Hyperintensities in 8421 Patients with Acute Ischemic Stroke

  • Hosung Kim
  • , Wi Sun Ryu
  • , Dawid Schellingerhout
  • , Jonghyeok Park
  • , Jinyong Chung
  • , Sang Wuk Jeong
  • , Dong Seok Gwak
  • , Beom Joon Kim
  • , Joon Tae Kim
  • , Keun Sik Hong
  • , Kyung Bok Lee
  • , Tai Hwan Park
  • , Jong Moo Park
  • , Kyusik Kang
  • , Yong Jin Cho
  • , Byung Chul Lee
  • , Kyung Ho Yu
  • , Mi Sun Oh
  • , Soo Joo Lee
  • , Jae Kwan Cha
  • Dae Hyun Kim, Jun Lee, Man Seok Park, Hee Joon Bae, Dong Eog Kim
  • University of Southern California
  • JLK Inc.
  • Dongguk University
  • University of Texas Health Science Center at Houston
  • Bioimaging Data Curation Center
  • Seoul National University
  • Chonnam National University
  • Inje University
  • Soonchunhyang University
  • Seoul Medical Center
  • Uijeongbu Eulji Medical Center
  • Eulji University
  • Hallym University
  • Dong-A University
  • Yeungnam University

Research output: Contribution to journalArticlepeer-review

7 Scopus citations

Abstract

BACKGROUND AND PURPOSE: To date, only a few small studies have attempted deep learning–based automatic segmentation of white matter hyperintensity (WMH) lesions in patients with cerebral infarction; this issue is complicated because stroke-related lesions can obscure WMH borders. We developed and validated deep learning algorithms to segment WMH lesions accurately in patients with cerebral infarction using multisite data sets involving 8421 patients with acute ischemic stroke. MATERIALS AND METHODS: We included 8421 patients with stroke from 9 centers in Korea. 2D UNet and squeeze-and-excitation (SE)UNet models were trained using 2408 FLAIR MRIs from 3 hospitals and validated using 6013 FLAIR MRIs from 6 hospitals. WMH segmentation performance was assessed by calculating the Dice similarity coefficient (DSC), the correlation coefficient, and the concordance correlation coefficient compared with a human-segmented criterion standard. In addition, we obtained an uncertainty index that represents overall ambiguity in the voxel classification for WMH segmentation in each patient based on the Kullback-Leibler divergence. RESULTS: In the training data set, the mean age was 67.4 (SD, 13.0) years, and 60.4% were men. The mean (95% CI) DSCs for UNet in internal testing and external validation were, respectively, 0.659 (0.649-0.669) and 0.710 (0.707-0.714), which were slightly lower than the reliability between humans (DSC ¼ 0.744; 95% CI, 0.738-0.751; P ¼ .031). Compared with the UNet, the SE-UNet demonstrated better performance, achieving a mean DSC of 0.675 (95% CI, 0.666–0.685; P, .001) in the internal testing and 0.722 (95% CI, 0.719-0.726; P, .001) in the external validation; moreover, it achieved high DSC values (ranging from 0.672 to 0.744) across multiple validation data sets. We observed a significant correlation between WMH volumes that were segmented automatically and manually for the UNet (r ¼ 0.917, P, .001), and it was even stronger for the SE-UNet (r ¼ 0.933, P, .001). The SE-UNet also attained a high concordance correlation coefficient (ranging from 0.841 to 0.956) in the external test data sets. In addition, the uncertainty indices in most patients (86%) in the external data sets were,0.35, with an average DSC of 0.744 in these patients. CONCLUSIONS: We developed and validated deep learning algorithms to segment WMH in patients with acute cerebral infarction using the largest-ever MRI data sets. In addition, we showed that the uncertainty index can be used to identify cases in which automatic WMH segmentation is less accurate and requires human review.

Original languageEnglish
Pages (from-to)1885-1894
Number of pages10
JournalAmerican Journal of Neuroradiology
Volume45
Issue number12
DOIs
StatePublished - 1 Dec 2024

Fingerprint

Dive into the research topics of 'Automated Segmentation of MRI White Matter Hyperintensities in 8421 Patients with Acute Ischemic Stroke'. Together they form a unique fingerprint.

Cite this