TY - JOUR
T1 - Comparison of fusion rate and clinical results between CaO-SiO2-P2O5-B2O3 bioactive glass ceramics spacer with titanium cages in posterior lumbar interbody fusion
AU - Lee, Jae Hyup
AU - Kong, Chang Bae
AU - Yang, Jae Jun
AU - Shim, Hee Jong
AU - Koo, Ki Hyoung
AU - Kim, Jeehyoung
AU - Lee, Choon Ki
AU - Chang, Bong Soon
N1 - Publisher Copyright:
© 2016 The Author(s)
PY - 2016/11/1
Y1 - 2016/11/1
N2 - Background Context The CaO-SiO2-P2O5-B2O3 glass ceramics spacer generates chemical bonding to adjacent bones with high mechanical stability to produce a union with the end plate, and ultimately stability. Purpose The authors aimed to compare the clinical efficacy and safety of CaO-SiO2-P2O5-B2O3 glass ceramics with a titanium cage that is widely used for posterior lumbar interbody fusion (PLIF) surgery in the clinical field. Study Design/Setting This is a prospective, stratified randomized, multicenter, single-blinded, comparator-controlled non-inferiority trial. Patient Sample The present study was conducted in four hospitals and enrolled a total of 86 patients between 30 and 80 years of age who required one-level PLIF due to severe spinal stenosis, spondylolisthesis, or huge disc herniation. Outcome Measures The Oswestry Disability Index (ODI), Short Form-36 Health Survey (SF-36), and pain visual analog scale (VAS) were assessed before surgery and at 3, 6, and 12 months after surgery. The spinal fusion rate was assessed at 6 and 12 months after surgery. Methods The spinal fusion rate and the area of fusion, subsidence of each CaO-SiO2-P2O5-B2O3 glass ceramics and titanium cage, and the extent of osteolysis were evaluated using a dynamic plain radiography and a three-dimensional computed tomography at 12 months after surgery. The present study was supported by BioAlpha, and some authors (JHL, C-KL, and B-SC) have stock ownership (<10,000 US dollars). Results From the plain radiography results, the 6-month fusion rates for the bioactive glass ceramics group and the titanium group were 89.7% and 91.4%, respectively. In addition, the 12-month fusion rates based on CT scan were 89.7% and 91.2%, respectively, showing no significant difference. However, the bone fusion area directly attached to the end plate of either bioactive glass ceramics or the titanium cage was significantly higher in the bioactive glass ceramics group than in the titanium group. The ODI, SF-36, back pain, and lower limb pain in both groups significantly improved after surgery, with no significant differences between the groups. No significant differences between the two groups were observed in the extent of subsidence and osteolysis. Conclusions In lumbar posterior interbody fusion surgery, CaO-SiO2-P2O5-B2O3 glass ceramics spacer showed a similar fusion rates and clinical outcomes compared with titanium cage.
AB - Background Context The CaO-SiO2-P2O5-B2O3 glass ceramics spacer generates chemical bonding to adjacent bones with high mechanical stability to produce a union with the end plate, and ultimately stability. Purpose The authors aimed to compare the clinical efficacy and safety of CaO-SiO2-P2O5-B2O3 glass ceramics with a titanium cage that is widely used for posterior lumbar interbody fusion (PLIF) surgery in the clinical field. Study Design/Setting This is a prospective, stratified randomized, multicenter, single-blinded, comparator-controlled non-inferiority trial. Patient Sample The present study was conducted in four hospitals and enrolled a total of 86 patients between 30 and 80 years of age who required one-level PLIF due to severe spinal stenosis, spondylolisthesis, or huge disc herniation. Outcome Measures The Oswestry Disability Index (ODI), Short Form-36 Health Survey (SF-36), and pain visual analog scale (VAS) were assessed before surgery and at 3, 6, and 12 months after surgery. The spinal fusion rate was assessed at 6 and 12 months after surgery. Methods The spinal fusion rate and the area of fusion, subsidence of each CaO-SiO2-P2O5-B2O3 glass ceramics and titanium cage, and the extent of osteolysis were evaluated using a dynamic plain radiography and a three-dimensional computed tomography at 12 months after surgery. The present study was supported by BioAlpha, and some authors (JHL, C-KL, and B-SC) have stock ownership (<10,000 US dollars). Results From the plain radiography results, the 6-month fusion rates for the bioactive glass ceramics group and the titanium group were 89.7% and 91.4%, respectively. In addition, the 12-month fusion rates based on CT scan were 89.7% and 91.2%, respectively, showing no significant difference. However, the bone fusion area directly attached to the end plate of either bioactive glass ceramics or the titanium cage was significantly higher in the bioactive glass ceramics group than in the titanium group. The ODI, SF-36, back pain, and lower limb pain in both groups significantly improved after surgery, with no significant differences between the groups. No significant differences between the two groups were observed in the extent of subsidence and osteolysis. Conclusions In lumbar posterior interbody fusion surgery, CaO-SiO2-P2O5-B2O3 glass ceramics spacer showed a similar fusion rates and clinical outcomes compared with titanium cage.
KW - Clinical trial
KW - Computed tomography
KW - Efficacy
KW - Fusion rate
KW - Glass ceramics
KW - Oswestry Disability Index
KW - Posterior lumbar interbody fusion
KW - Prospective study
KW - Safety
KW - Titanium cage
UR - http://www.scopus.com/inward/record.url?scp=84994353584&partnerID=8YFLogxK
U2 - 10.1016/j.spinee.2016.07.531
DO - 10.1016/j.spinee.2016.07.531
M3 - Article
C2 - 27498334
AN - SCOPUS:84994353584
SN - 1529-9430
VL - 16
SP - 1367
EP - 1376
JO - Spine Journal
JF - Spine Journal
IS - 11
ER -