TY - JOUR
T1 - Comparison of Fusion, Subsidence, and Clinical Results Between 3D-Printed Porous Titanium Cage and Polyetheretherketone Cage in Posterior Lumbar Interbody Fusion
T2 - A Minimum of 2 Years Follow-Up
AU - Yang, Jae Jun
AU - Kim, Dong Min
AU - Park, Sehan
N1 - Publisher Copyright:
© 2023 Elsevier Inc.
PY - 2023/9
Y1 - 2023/9
N2 - Objective: The occurrence of early osteointegration and reduced modulus of elasticity have been proved with 3-dimensinally (3D) printed porous titanium (3DP-titanium) cages used for posterior lumbar interbody fusion (PLIF). The present study was conducted to demonstrate the fusion rate, subsidence, and clinical outcomes for the 3DP-titanium cage in PLIF and to compare its results with those of the polyetheretherketone (PEEK) cage. Methods: A total of 150 patients who underwent 1–2-level PLIF and were followed up for >2 years were retrospectively reviewed. The fusion rates, subsidence, segmental lordosis, visual analog scale (VAS) score for back pain, VAS score for leg pain, and Oswestry disability index were assessed. Results: A higher 1-year (3DP-titanium, 86.9%; PEEK, 67.7%; P = 0.002) and 2-year (3DP-titanium, 92.9%; PEEK, 82.3%; P = 0.037) fusion rate could be achieved with 3DP-titanium cages for PLIF than with PEEK cages. The amount of subsidence (3DP-titanium, 1.4 ± 1.6 mm; PEEK, 1.9 ± 1.8 mm; P = 0.092) and incidence of significant subsidence (3DP-titanium, 17.9%; PEEK, 23.4%; P = 0.389) was not significantly different between the 2 materials. Furthermore, the VAS score for back pain and leg pain and Oswestry disability index were not significantly different between the 2 groups. On logistic regression analysis, cage material (P = 0.027) showed a significant association with fusion, and the number of levels fused (P = 0.012) was associated with subsidence. Conclusions: The 3DP-titanium cage resulted in a higher fusion rate than the PEEK cage when used for PLIF. The subsidence rate did not differ significantly between the 2 cage materials. Therefore, the 3DP-titanium cage can be safely used for PLIF, considering its stable construct.
AB - Objective: The occurrence of early osteointegration and reduced modulus of elasticity have been proved with 3-dimensinally (3D) printed porous titanium (3DP-titanium) cages used for posterior lumbar interbody fusion (PLIF). The present study was conducted to demonstrate the fusion rate, subsidence, and clinical outcomes for the 3DP-titanium cage in PLIF and to compare its results with those of the polyetheretherketone (PEEK) cage. Methods: A total of 150 patients who underwent 1–2-level PLIF and were followed up for >2 years were retrospectively reviewed. The fusion rates, subsidence, segmental lordosis, visual analog scale (VAS) score for back pain, VAS score for leg pain, and Oswestry disability index were assessed. Results: A higher 1-year (3DP-titanium, 86.9%; PEEK, 67.7%; P = 0.002) and 2-year (3DP-titanium, 92.9%; PEEK, 82.3%; P = 0.037) fusion rate could be achieved with 3DP-titanium cages for PLIF than with PEEK cages. The amount of subsidence (3DP-titanium, 1.4 ± 1.6 mm; PEEK, 1.9 ± 1.8 mm; P = 0.092) and incidence of significant subsidence (3DP-titanium, 17.9%; PEEK, 23.4%; P = 0.389) was not significantly different between the 2 materials. Furthermore, the VAS score for back pain and leg pain and Oswestry disability index were not significantly different between the 2 groups. On logistic regression analysis, cage material (P = 0.027) showed a significant association with fusion, and the number of levels fused (P = 0.012) was associated with subsidence. Conclusions: The 3DP-titanium cage resulted in a higher fusion rate than the PEEK cage when used for PLIF. The subsidence rate did not differ significantly between the 2 cage materials. Therefore, the 3DP-titanium cage can be safely used for PLIF, considering its stable construct.
KW - 3D-printed porous titanium
KW - Cage
KW - Extra-cage bone bridging
KW - Fusion
KW - Micromotion
KW - Modulus of elasticity
KW - Polyetheretherketone
KW - Posterior lumbar interbody fusion
KW - Subsidence
UR - http://www.scopus.com/inward/record.url?scp=85166181514&partnerID=8YFLogxK
U2 - 10.1016/j.wneu.2023.06.132
DO - 10.1016/j.wneu.2023.06.132
M3 - Article
C2 - 37419312
AN - SCOPUS:85166181514
SN - 1878-8750
VL - 177
SP - e732-e741
JO - World Neurosurgery
JF - World Neurosurgery
ER -