TY - JOUR
T1 - Comparison of Optical and Electrical Sensor Characteristics for Efficient Analysis of Attachment and Detachment of Aptamer
AU - Park, Yejin
AU - Dang, Thinh Viet
AU - Jeong, Uiseok
AU - Kim, Moon Il
AU - Kim, Jinsik
N1 - Publisher Copyright:
© 2022 by the authors.
PY - 2022/11
Y1 - 2022/11
N2 - Nucleic acid aptamer-based research has focused on achieving the highest performance for bioassays. However, there are limitations in evaluating the affinity for the target analytes in these nucleic acid aptamer-based bioassays. In this study, we mainly propose graphene oxide (GO)-based electrical and optical analyses to efficiently evaluate the affinity between an aptamer and its target. We found that an aptamer-coupled GO-based chip with an electrical resistance induced by a field-effect transistor, with aptamers as low as 100 pM, can detect the target, thrombin, at yields as low as 250 pM within five minutes. In the optical approach, the fluorescent dye-linked aptamer, as low as 100 nM, was efficiently used with GO, enabling the sensitive detection of thrombin at yields as low as 5 nM. The cantilever type of mechanical analysis also demonstrated the intuitive aptamer–thrombin reaction in the signal using dBm units. Finally, a comparison of electrical and optical sensors’ characteristics was introduced in the attachment and detachment of aptamer to propose an efficient analysis that can be utilized for various aptamer-based research fields.
AB - Nucleic acid aptamer-based research has focused on achieving the highest performance for bioassays. However, there are limitations in evaluating the affinity for the target analytes in these nucleic acid aptamer-based bioassays. In this study, we mainly propose graphene oxide (GO)-based electrical and optical analyses to efficiently evaluate the affinity between an aptamer and its target. We found that an aptamer-coupled GO-based chip with an electrical resistance induced by a field-effect transistor, with aptamers as low as 100 pM, can detect the target, thrombin, at yields as low as 250 pM within five minutes. In the optical approach, the fluorescent dye-linked aptamer, as low as 100 nM, was efficiently used with GO, enabling the sensitive detection of thrombin at yields as low as 5 nM. The cantilever type of mechanical analysis also demonstrated the intuitive aptamer–thrombin reaction in the signal using dBm units. Finally, a comparison of electrical and optical sensors’ characteristics was introduced in the attachment and detachment of aptamer to propose an efficient analysis that can be utilized for various aptamer-based research fields.
KW - aptamer
KW - cantilever-integrated waveguide
KW - field-effect transistor
KW - fluorescence quenching
KW - graphene oxide
KW - thrombin detection
UR - http://www.scopus.com/inward/record.url?scp=85141891521&partnerID=8YFLogxK
U2 - 10.3390/bios12110979
DO - 10.3390/bios12110979
M3 - Article
C2 - 36354488
AN - SCOPUS:85141891521
SN - 2079-6374
VL - 12
JO - Biosensors
JF - Biosensors
IS - 11
M1 - 979
ER -