TY - JOUR
T1 - Deep Learning-Based Image Conversion Improves the Reproducibility of Computed Tomography Radiomics Features
T2 - A Phantom Study
AU - Lee, Seul Bi
AU - Cho, Yeon Jin
AU - Hong, Youngtaek
AU - Jeong, Dawun
AU - Lee, Jina
AU - Kim, Soo Hyun
AU - Lee, Seunghyun
AU - Choi, Young Hun
N1 - Publisher Copyright:
© Wolters Kluwer Health, Inc. All rights reserved.
PY - 2022/5/1
Y1 - 2022/5/1
N2 - Objectives This study aimed to evaluate the usefulness of deep learning-based image conversion to improve the reproducibility of computed tomography (CT) radiomics features. Materials and Methods This study was conducted using an abdominal phantom with liver nodules. We developed an image conversion algorithm using a residual feature aggregation network to reproduce radiomics features with CT images under various CT protocols and reconstruction kernels. External validation was performed using images from different scanners, consisting of 8 different protocols. To evaluate the variability of radiomics features, regions of interest (ROIs) were drawn by targeting the liver parenchyma, vessels, paraspinal area, and liver nodules. We extracted 18 first-order, 68 second-order, and 688 wavelet radiomics features. Measurement variability was assessed using the concordance correlation coefficient (CCC), compared with the ground-truth image. Results In the ROI-based analysis, there was an 83.3% improvement of CCC (80/96; 4 ROIs with 3 categories of radiomics features and 8 protocols) in synthetic images compared with the original images. Among them, the 56 CCC pairs showed a significant increase after image synthesis. In the radiomics feature-based analysis, 62.0% (3838 of 6192; 774 radiomics features with 8 protocols) features showed increased CCC after image synthesis, and a significant increase was noted in 26.9% (1663 of 6192) features. In particular, the first-order feature (79.9%, 115/144) showed better improvement in terms of the reproducibility of radiomics feature than the second-order (59.9%, 326/544) or wavelet feature (61.7%, 3397/5504). Conclusions Our study demonstrated that a deep learning model for image conversion can improve the reproducibility of radiomics features across various CT protocols, reconstruction kernels, and CT scanners.
AB - Objectives This study aimed to evaluate the usefulness of deep learning-based image conversion to improve the reproducibility of computed tomography (CT) radiomics features. Materials and Methods This study was conducted using an abdominal phantom with liver nodules. We developed an image conversion algorithm using a residual feature aggregation network to reproduce radiomics features with CT images under various CT protocols and reconstruction kernels. External validation was performed using images from different scanners, consisting of 8 different protocols. To evaluate the variability of radiomics features, regions of interest (ROIs) were drawn by targeting the liver parenchyma, vessels, paraspinal area, and liver nodules. We extracted 18 first-order, 68 second-order, and 688 wavelet radiomics features. Measurement variability was assessed using the concordance correlation coefficient (CCC), compared with the ground-truth image. Results In the ROI-based analysis, there was an 83.3% improvement of CCC (80/96; 4 ROIs with 3 categories of radiomics features and 8 protocols) in synthetic images compared with the original images. Among them, the 56 CCC pairs showed a significant increase after image synthesis. In the radiomics feature-based analysis, 62.0% (3838 of 6192; 774 radiomics features with 8 protocols) features showed increased CCC after image synthesis, and a significant increase was noted in 26.9% (1663 of 6192) features. In particular, the first-order feature (79.9%, 115/144) showed better improvement in terms of the reproducibility of radiomics feature than the second-order (59.9%, 326/544) or wavelet feature (61.7%, 3397/5504). Conclusions Our study demonstrated that a deep learning model for image conversion can improve the reproducibility of radiomics features across various CT protocols, reconstruction kernels, and CT scanners.
KW - artificial intelligence
KW - CT acquisition
KW - quality control
KW - radiomics
KW - reproducibility
UR - https://www.scopus.com/pages/publications/85124876474
U2 - 10.1097/RLI.0000000000000839
DO - 10.1097/RLI.0000000000000839
M3 - Article
C2 - 34839305
AN - SCOPUS:85124876474
SN - 0020-9996
VL - 57
SP - 308
EP - 317
JO - Investigative Radiology
JF - Investigative Radiology
IS - 5
ER -