TY - JOUR
T1 - Direct and rapid quantitation of ephedrines in human urine by paper spray ionization/high resolution mass spectrometry
AU - Jeong, Eun Sook
AU - Kim, Ki Hun
AU - Cha, Eunju
AU - Kwon, Oh Seung
AU - Cha, Sangwon
AU - Lee, Jaeick
N1 - Publisher Copyright:
© 2016 Elsevier B.V.
PY - 2016/8/15
Y1 - 2016/8/15
N2 - A rapid and direct paper spray ionization/mass spectrometry (PSI/MS) method was developed for quantitative analysis of ephedrine, pseudoephedrine, norpseudoephedrine, and methylephedrine in human urine. This method involves the use of a triangular filter paper and high-resolution mass spectrometry, where the molecular ions of ephedrines were generated by applying high voltage after loading the spray solvent to the paper which urine sample was pre-loaded. Small amounts (2 μL) of urine spiked with an internal standard were directly analyzed for ephedrines. The PSI/MS method was validated for linearity, within- and between-run precision, accuracy, and limit of detection. The results showed good linearity (R2 ≥ 0.9928) and acceptable precision and accuracy. Furthermore, the accuracy of the method was assessed by analyzing a blind urine sample from World Anti-Doping Agency and comparing the measured concentrations with the nominal concentrations. This test resulted in accuracies ranging from 96.4 to 106.1%, indicating that the PSI/MS method has the potential to be an alternative technique for the fast quantitation of ephedrines in doping control analysis.
AB - A rapid and direct paper spray ionization/mass spectrometry (PSI/MS) method was developed for quantitative analysis of ephedrine, pseudoephedrine, norpseudoephedrine, and methylephedrine in human urine. This method involves the use of a triangular filter paper and high-resolution mass spectrometry, where the molecular ions of ephedrines were generated by applying high voltage after loading the spray solvent to the paper which urine sample was pre-loaded. Small amounts (2 μL) of urine spiked with an internal standard were directly analyzed for ephedrines. The PSI/MS method was validated for linearity, within- and between-run precision, accuracy, and limit of detection. The results showed good linearity (R2 ≥ 0.9928) and acceptable precision and accuracy. Furthermore, the accuracy of the method was assessed by analyzing a blind urine sample from World Anti-Doping Agency and comparing the measured concentrations with the nominal concentrations. This test resulted in accuracies ranging from 96.4 to 106.1%, indicating that the PSI/MS method has the potential to be an alternative technique for the fast quantitation of ephedrines in doping control analysis.
KW - Doping control analysis
KW - Ephedrine
KW - Paper spray ionization/mass spectrometry
UR - https://www.scopus.com/pages/publications/84977671807
U2 - 10.1016/j.jchromb.2016.06.040
DO - 10.1016/j.jchromb.2016.06.040
M3 - Article
C2 - 27393909
AN - SCOPUS:84977671807
SN - 1570-0232
VL - 1028
SP - 237
EP - 241
JO - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
JF - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
ER -