Electrochemical coupled immunosensing platform based on graphene oxide/gold nanocomposite for sensitive detection of Cronobacter sakazakii in powdered infant formula

Shruti Shukla, Yuvaraj Haldorai, Vivek K. Bajpai, Arunkumar Rengaraj, Seung Kyu Hwang, Xinjie Song, Myunghee Kim, Yun Suk Huh, Young Kyu Han

Research output: Contribution to journalArticlepeer-review

54 Scopus citations

Abstract

A sensitive electrochemical immunosensing platform for the detection of Cronobacter sakazakii was developed using a graphene oxide/gold (GO/Au) composite. Transmission electron microscopy showed that the Au nanoparticles, with an average size of < 30 nm, were well dispersed on the GO surface. For the detection of C. sakazakii, a polyclonal anti-C. sakazakii antibody (IgG) was covalently immobilized to the Au nanoparticles on the surface of the GO/Au composite coated glassy carbon electrode (GCE). The electrochemical sensing performance of immunofunctionalized GCE was characterized by cyclic voltammetry and differential pulse voltammetry. Under optimized conditions, in pure culture there was a linear relationship between electrical signal and C. sakazakii levels over the range 2.0 × 102–2.0 × 107 cfu/mL (R2 = 0.999), with a detection limit of 2.0 × 101 cfu/mL. The total analytical time was 15 min per sample. The C. sakazakii electrochemical immunosensing assay was able to successfully detect 2.0 × 101 cfu/mL of C. sakazakii in artificially contaminated powdered infant formula without any enrichment or pre-enrichment steps. Furthermore, the recovery rates of the C. sakazakii electrochemical immunosensing assay following spiking of powdered infant formula with different concentrations of C. sakazakii (cfu/mL) were 82.58% at 2.0 × 101 cfu/mL, 84.86% at 2.0 × 102 cfu/mL, and 95.40% at 2.0 × 103 cfu/mL. The C. sakazakii electrochemical immunosensing assay had good selectivity, reproducibility, and reactivity compared with other Cronobacter spp. and/or pathogens belonging to other genera, indicating its significant potential in the clinical diagnosis of C. sakazakii.

Original languageEnglish
Pages (from-to)139-149
Number of pages11
JournalBiosensors and Bioelectronics
Volume109
DOIs
StatePublished - 30 Jun 2018

Keywords

  • Cronobacter sakazakii
  • Electrochemical immunosensing
  • Graphene oxide–gold composite
  • Pathogen detection
  • Powdered infant formula