TY - JOUR
T1 - High Performance Cylindrical Capacitor as a Relative Humidity Sensor for Wearable Computing Devices
AU - Jang, Juhee
AU - Han, Jeong In
N1 - Publisher Copyright:
© 2017 The Electrochemical Society.
PY - 2017
Y1 - 2017
N2 - First, we designed and fabricated a cylindrical humidity sensing capacitor. In addition, we suggested its suitability as a capacitive RH sensor for wearable computing devices. Aluminum (Al) thin film for electrodes was uniformly deposited on a single fiber that consists of one fiber. The exposed area of the polyimide (PI) was particularly situated on an outer electrode to promote its moisture sensing capability. The capacitance change according to the relative humidity is indicated with a specific S-shape due to the interval adsorption reactions between the imide group and the water molecules. An adsorption mechanism is proposed based on the theory of the volume filling of micropores (TVFM), and the effect of PI thickness was investigated. In addition, the response times for adsorption and desorption were measured by changing the moisture condition. Moreover, with a repetitive bending test, the device durability was inspected by implementing the bending times and bending curvature radius.
AB - First, we designed and fabricated a cylindrical humidity sensing capacitor. In addition, we suggested its suitability as a capacitive RH sensor for wearable computing devices. Aluminum (Al) thin film for electrodes was uniformly deposited on a single fiber that consists of one fiber. The exposed area of the polyimide (PI) was particularly situated on an outer electrode to promote its moisture sensing capability. The capacitance change according to the relative humidity is indicated with a specific S-shape due to the interval adsorption reactions between the imide group and the water molecules. An adsorption mechanism is proposed based on the theory of the volume filling of micropores (TVFM), and the effect of PI thickness was investigated. In addition, the response times for adsorption and desorption were measured by changing the moisture condition. Moreover, with a repetitive bending test, the device durability was inspected by implementing the bending times and bending curvature radius.
UR - http://www.scopus.com/inward/record.url?scp=85016566787&partnerID=8YFLogxK
U2 - 10.1149/2.1121704jes
DO - 10.1149/2.1121704jes
M3 - Article
AN - SCOPUS:85016566787
SN - 0013-4651
VL - 164
SP - B136-B141
JO - Journal of the Electrochemical Society
JF - Journal of the Electrochemical Society
IS - 4
ER -