J-tube technique for double-j stent insertion during laparoscopic upper urinary tract surgical procedures

Hyung Suk Kim, Byung Ki Lee, Jin Woo Jung, Jung Keun Lee, Seok Soo Byun, Sang Eun Lee, Chang Wook Jeong

Research output: Contribution to journalArticlepeer-review

3 Scopus citations

Abstract

Double-J stent insertion has been generally performed during laparoscopic upper urinary tract (UUT) surgical procedures to prevent transient urinary tract obstruction and postoperative flank pain from ureteral edema and blood clots. Several restrictive conditions that make this procedure difficult and time consuming, however, include the coiled distal ends of the flexible Double-J stent and the limited bending angle of the laparoscopic instruments. To overcome these limitations, we devised a Double-J stent insertion method using the new J-tube technique. Between July 2011 and May 2013, Double-J stents were inserted using the J-tube technique in 33 patients who underwent a laparoscopic UUT surgical procedure by a single surgeon. The mean stent placement time was 4.8±2.7 minutes, and there were no intraoperative complications. In conclusion, the J-tube technique is a safe and time-saving method for Double-J stent insertion during laparoscopic surgical procedures.

Original languageEnglish
Pages (from-to)1278-1281
Number of pages4
JournalJournal of Endourology
Volume28
Issue number11
DOIs
StatePublished - 2014

Fingerprint

Dive into the research topics of 'J-tube technique for double-j stent insertion during laparoscopic upper urinary tract surgical procedures'. Together they form a unique fingerprint.

Cite this