TY - JOUR
T1 - Palladium nanoparticles anchored MoS2-MXene composite modified electrode for rapid sensing of toxic bisphenol A in aqueous media
AU - Ezhil Vilian, A. T.
AU - Tiwari, Jitendra N.
AU - Alhammadi, Munirah
AU - Bhaskaran, Gokul
AU - Hwang, Seung Kyu
AU - Kim, Suheon
AU - Kumar, Krishan
AU - Senthil Kumar, Annamalai
AU - Suk Huh, Yun
AU - Han, Young Kyu
N1 - Publisher Copyright:
© 2023 Elsevier B.V.
PY - 2023/8/1
Y1 - 2023/8/1
N2 - Bisphenol A (BPA) is a commonly used, highly toxic organic phenolic that can damage the human nervous, reproductive, and immune systems, and thus, a rapid onsite test method is required to detect BPA in environmental samples. In this research, we coated screen-printed carbon electrodes (SPCEs) with Pd nanoparticles (NPs) anchored on a MoS2-modified MXene nanoarchitecture for the accurate onsite sensing of BPA contamination in aquatic environmental samples. Pd-MoS2-MXene-SPCEs were prepared using a one-step hydrothermal technique followed by chemical reduction. The optimized SPCE had a low Rct of 63 Ω and excellent electrocatalytic efficiency for BPA oxidation and a remarkably high current density at the lowest anodic potential (0.57 V vs. Ag/AgCl) in 0.05 M phosphate buffer (pH 7). The charge-transfer rate (ks) and the saturation absorption capacity (or surface-excess) (Γ) of the Pd-MoS2-MXene-SPCEs were 3.14 s−1 and 5.62 × 10-9 mol cm−2, respectively. Under optimal conditions, square wave voltammetry responses to BPA concentration were linear in the range 5 to 175 nM, and exhibited high sensitivity (16.205 μA nM−1 cm−2) and a detection limit of 0.12 nM (3.3 σ/s). The optimized SPCE exhibited high reproducibility, reusability, and repeatability with a relative standard deviation (RSD) of < 5.0% and excellent stability and retained 89.2% of its initial sensitivity after 30 days of storage for the onsite sensing of BPA. The prepared sensor showed excellent selectivity for the quantification of BPA even in the presence of electrochemically active interfering compounds such as drugs, pollutants, biological substances, and some common cations/anions. Real-time quantitative analysis of BPA in milk and river and lake water samples was performed, and acceptable recoveries were obtained (from 89.1 to 107.8%) with an RSD of 2.2–3.8%, demonstrating an accuracy similar to that of HPLC.
AB - Bisphenol A (BPA) is a commonly used, highly toxic organic phenolic that can damage the human nervous, reproductive, and immune systems, and thus, a rapid onsite test method is required to detect BPA in environmental samples. In this research, we coated screen-printed carbon electrodes (SPCEs) with Pd nanoparticles (NPs) anchored on a MoS2-modified MXene nanoarchitecture for the accurate onsite sensing of BPA contamination in aquatic environmental samples. Pd-MoS2-MXene-SPCEs were prepared using a one-step hydrothermal technique followed by chemical reduction. The optimized SPCE had a low Rct of 63 Ω and excellent electrocatalytic efficiency for BPA oxidation and a remarkably high current density at the lowest anodic potential (0.57 V vs. Ag/AgCl) in 0.05 M phosphate buffer (pH 7). The charge-transfer rate (ks) and the saturation absorption capacity (or surface-excess) (Γ) of the Pd-MoS2-MXene-SPCEs were 3.14 s−1 and 5.62 × 10-9 mol cm−2, respectively. Under optimal conditions, square wave voltammetry responses to BPA concentration were linear in the range 5 to 175 nM, and exhibited high sensitivity (16.205 μA nM−1 cm−2) and a detection limit of 0.12 nM (3.3 σ/s). The optimized SPCE exhibited high reproducibility, reusability, and repeatability with a relative standard deviation (RSD) of < 5.0% and excellent stability and retained 89.2% of its initial sensitivity after 30 days of storage for the onsite sensing of BPA. The prepared sensor showed excellent selectivity for the quantification of BPA even in the presence of electrochemically active interfering compounds such as drugs, pollutants, biological substances, and some common cations/anions. Real-time quantitative analysis of BPA in milk and river and lake water samples was performed, and acceptable recoveries were obtained (from 89.1 to 107.8%) with an RSD of 2.2–3.8%, demonstrating an accuracy similar to that of HPLC.
KW - Bisphenol A
KW - Electrochemical sensor
KW - MXene nanosheets
KW - Molybdenum disulfide
KW - Pd nanoparticles
KW - Square wave voltammetry
UR - http://www.scopus.com/inward/record.url?scp=85161893581&partnerID=8YFLogxK
U2 - 10.1016/j.cej.2023.144017
DO - 10.1016/j.cej.2023.144017
M3 - Article
AN - SCOPUS:85161893581
SN - 1385-8947
VL - 469
JO - Chemical Engineering Journal
JF - Chemical Engineering Journal
M1 - 144017
ER -