TY - JOUR
T1 - Predicting Obstructive Sleep Apnea Based on Computed Tomography Scans Using Deep Learning Models
AU - Kim, Jeong Whun
AU - Lee, Kyungsu
AU - Kim, Hyun Jik
AU - Park, Hae Chan
AU - Hwang, Jae Youn
AU - Park, Seok Won
AU - Kong, Hyoun Joong
AU - Kim, Jin Youp
N1 - Publisher Copyright:
Copyright © 2024 by the American Thoracic Society.
PY - 2024/7/15
Y1 - 2024/7/15
N2 - Rationale: The incidence of clinically undiagnosed obstructive sleep apnea (OSA) is high among the general population because of limited access to polysomnography. Computed tomography (CT) of craniofacial regions obtained for other purposes can be beneficial in predicting OSA and its severity. Objectives: To predict OSA and its severity based on paranasal CT using a three-dimensional deep learning algorithm. Methods: One internal dataset (N = 798) and two external datasets (N = 135 and N = 85) were used in this study. In the internal dataset, 92 normal participants and 159 with mild, 201 with moderate, and 346 with severe OSA were enrolled to derive the deep learning model. A multimodal deep learning model was elicited from the connection between a three-dimensional convolutional neural network-based part treating unstructured data (CT images) and a multilayer perceptron-based part treating structured data (age, sex, and body mass index) to predict OSA and its severity. Measurements and Main Results: In a four-class classification for predicting the severity of OSA, the AirwayNet-MM-H model (multimodal model with airway-highlighting preprocessing algorithm) showed an average accuracy of 87.6% (95% confidence interval [CI], 86.8-88.6%) in the internal dataset and 84.0% (95% CI, 83.0-85.1%) and 86.3% (95% CI, 85.3-87.3%) in the two external datasets, respectively. In the two-class classification for predicting significant OSA (moderate to severe OSA), the area under the receiver operating characteristic curve, accuracy, sensitivity, specificity, and F1 score were 0.910 (95% CI, 0.899-0.922), 91.0% (95% CI, 90.1-91.9%), 89.9% (95% CI, 88.8-90.9%), 93.5% (95% CI, 92.7-94.3%), and 93.2% (95% CI, 92.5-93.9%), respectively, in the internal dataset. Furthermore, the diagnostic performance of the Airway Net-MM-H model outperformed that of the other six state-of-the-art deep learning models in terms of accuracy for both four- and two-class classifications and area under the receiver operating characteristic curve for two-class classification (P, 0.001). Conclusions: A novel deep learning model, including a multimodal deep learning model and an airway-highlighting preprocessing algorithm from CT images obtained for other purposes, can provide significantly precise outcomes for OSA diagnosis.
AB - Rationale: The incidence of clinically undiagnosed obstructive sleep apnea (OSA) is high among the general population because of limited access to polysomnography. Computed tomography (CT) of craniofacial regions obtained for other purposes can be beneficial in predicting OSA and its severity. Objectives: To predict OSA and its severity based on paranasal CT using a three-dimensional deep learning algorithm. Methods: One internal dataset (N = 798) and two external datasets (N = 135 and N = 85) were used in this study. In the internal dataset, 92 normal participants and 159 with mild, 201 with moderate, and 346 with severe OSA were enrolled to derive the deep learning model. A multimodal deep learning model was elicited from the connection between a three-dimensional convolutional neural network-based part treating unstructured data (CT images) and a multilayer perceptron-based part treating structured data (age, sex, and body mass index) to predict OSA and its severity. Measurements and Main Results: In a four-class classification for predicting the severity of OSA, the AirwayNet-MM-H model (multimodal model with airway-highlighting preprocessing algorithm) showed an average accuracy of 87.6% (95% confidence interval [CI], 86.8-88.6%) in the internal dataset and 84.0% (95% CI, 83.0-85.1%) and 86.3% (95% CI, 85.3-87.3%) in the two external datasets, respectively. In the two-class classification for predicting significant OSA (moderate to severe OSA), the area under the receiver operating characteristic curve, accuracy, sensitivity, specificity, and F1 score were 0.910 (95% CI, 0.899-0.922), 91.0% (95% CI, 90.1-91.9%), 89.9% (95% CI, 88.8-90.9%), 93.5% (95% CI, 92.7-94.3%), and 93.2% (95% CI, 92.5-93.9%), respectively, in the internal dataset. Furthermore, the diagnostic performance of the Airway Net-MM-H model outperformed that of the other six state-of-the-art deep learning models in terms of accuracy for both four- and two-class classifications and area under the receiver operating characteristic curve for two-class classification (P, 0.001). Conclusions: A novel deep learning model, including a multimodal deep learning model and an airway-highlighting preprocessing algorithm from CT images obtained for other purposes, can provide significantly precise outcomes for OSA diagnosis.
KW - OSA
KW - X-ray
KW - computed tomography
KW - deep learning
UR - https://www.scopus.com/pages/publications/85199078842
U2 - 10.1164/rccm.202304-0767OC
DO - 10.1164/rccm.202304-0767OC
M3 - Article
C2 - 38471111
AN - SCOPUS:85199078842
SN - 1073-449X
VL - 210
SP - 211
EP - 221
JO - American Journal of Respiratory and Critical Care Medicine
JF - American Journal of Respiratory and Critical Care Medicine
IS - 2
ER -