Abstract
A real-time per-clock-cycle energy measurement technique is presented for power analysis and the reduction of energy consumption of synchronous state machines. This technique guarantees accuracy with a sampling rate of twice the clock frequency under spiky current draw conditions common in digital systems. In addition, it acquires the energy consumption profile in real-time, and therefore does not require repeated operation of the target system.
| Original language | English |
|---|---|
| Pages (from-to) | 1169-1171 |
| Number of pages | 3 |
| Journal | Electronics Letters |
| Volume | 36 |
| Issue number | 13 |
| DOIs | |