Abstract
A highly efficient runlength-limited (RLL) code with the minimum run-length constraint d=3 and the maximum run-length constraint k=7 was proposed with CMOS implementation result. The capacity of the (3,7) code was found to be 0.4057 which suggested that the code rate 2/5 code was allowable. The efficiency of the proposed code was 98.6% and the density ratio was 1.6.
Original language | English |
---|---|
Pages (from-to) | BR10 |
Journal | Digests of the Intermag Conference |
State | Published - 2002 |
Event | 2002 IEEE International Magnetics Conference-2002 IEEE INTERMAG - Amsterdam, Netherlands Duration: 28 Apr 2002 → 2 May 2002 |