TY - JOUR
T1 - Silk and collagen scaffolds for tendon reconstruction
AU - Kwon, Soon Yong
AU - Chung, Jin Wha
AU - Park, Hee Jung
AU - Jiang, Yuan Yuan
AU - Park, Jung Keug
AU - Seo, Young Kwon
PY - 2014/4
Y1 - 2014/4
N2 - In this study, silk thread (Bombyx mori) was braided to a tube-like shape and sericin was removed from the silk tube. Thereafter, collagen/chondroitin-6- sulfate solution was poured into the silk tube, and the lyophilization process was performed. To assess the inflammatory response in vivo, raw silk and sericin-free silk tubes were implanted in the subcutaneous layer of mice. After 10 days of in vivo implantation, mild inflammatory responses were observed around the sericin-free silk tubes, and severe inflammation with the presence of neutrophils and macrophages was observed around the raw silk tubes. At 24 weeks post implantation, the regenerated tendon had a thick, cylindrical, grayish fibrous structure and a shiny white appearance, similar to that of the native tendon in the rabbit model of tendon defect. The average tensile strength of the native tendons was 220 6 20 N, whereas the average tensile strength of the regenerated tendons was 167 6 30 N and the diameter of the regenerated tendon (3 6 0.2 mm) was similar to that of the native tendons (4 6 0.3 mm). Histologically, the regenerated tendon resembled the native tendon, and all the regenerated tissues showed organized bundles of crimped fibers. Masson trichrome staining was performed for detecting collagen synthesis, and it showed that the artificial tendon was replaced by new collagen fibers and extracellular matrix. However, the regenerated tendon showed fibrosis to a certain degree. In conclusion, the artificial tendon, comprising a braided silk tube and lyophilized collagen sponge, was optimal for tendon reconstruction. Thus, this study showed an improved regeneration of neo-tendon tissues, which have the structure and tensile strength of the native tendon, with the use of the combination of collagen and silk scaffold.
AB - In this study, silk thread (Bombyx mori) was braided to a tube-like shape and sericin was removed from the silk tube. Thereafter, collagen/chondroitin-6- sulfate solution was poured into the silk tube, and the lyophilization process was performed. To assess the inflammatory response in vivo, raw silk and sericin-free silk tubes were implanted in the subcutaneous layer of mice. After 10 days of in vivo implantation, mild inflammatory responses were observed around the sericin-free silk tubes, and severe inflammation with the presence of neutrophils and macrophages was observed around the raw silk tubes. At 24 weeks post implantation, the regenerated tendon had a thick, cylindrical, grayish fibrous structure and a shiny white appearance, similar to that of the native tendon in the rabbit model of tendon defect. The average tensile strength of the native tendons was 220 6 20 N, whereas the average tensile strength of the regenerated tendons was 167 6 30 N and the diameter of the regenerated tendon (3 6 0.2 mm) was similar to that of the native tendons (4 6 0.3 mm). Histologically, the regenerated tendon resembled the native tendon, and all the regenerated tissues showed organized bundles of crimped fibers. Masson trichrome staining was performed for detecting collagen synthesis, and it showed that the artificial tendon was replaced by new collagen fibers and extracellular matrix. However, the regenerated tendon showed fibrosis to a certain degree. In conclusion, the artificial tendon, comprising a braided silk tube and lyophilized collagen sponge, was optimal for tendon reconstruction. Thus, this study showed an improved regeneration of neo-tendon tissues, which have the structure and tensile strength of the native tendon, with the use of the combination of collagen and silk scaffold.
KW - Artificial tendon
KW - Collagen
KW - Composite scaffold
KW - Silk tube
UR - http://www.scopus.com/inward/record.url?scp=84902195258&partnerID=8YFLogxK
U2 - 10.1177/0954411914528890
DO - 10.1177/0954411914528890
M3 - Article
C2 - 24705339
AN - SCOPUS:84902195258
SN - 0954-4119
VL - 228
SP - 388
EP - 396
JO - Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
JF - Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
IS - 4