Simultaneous determination of flurbiprofen and its hydroxy metabolite in human plasma by liquid chromatography-tandem mass spectrometry for clinical application

  • Hye In Lee
  • , Chang Ik Choi
  • , Ji Yeong Byeon
  • , Jung Eun Lee
  • , So Young Park
  • , Young Hoon Kim
  • , Se Hyung Kim
  • , Yun Jeong Lee
  • , Choon Gon Jang
  • , Seok Yong Lee

Research output: Contribution to journalArticlepeer-review

14 Scopus citations

Abstract

Flurbiprofen (FLB) is one of the phenylalkanoic acid derivatives of non-steroidal anti-inflammatory drugs used for the management of pain and inflammation in patients with arthritis. We developed and validated a rapid and sensitive high-performance liquid chromatography analytical method utilizing tandem mass spectrometry (HPLC-MS/MS) for the simultaneous determination of FLB and its major metabolite, 4'-hydroxyflurbiprofen (4'-OH-FLB), in human plasma. Probenecid was used as an internal standard (IS). After liquid-liquid extraction with methyl t-butyl ether, chromatographic separation of the two analytes was achieved using a reversed-phase Luna C18 column (2.0mm×50mm, 5μm particles) with a mobile phase of 10mM ammonium formate buffer (pH 3.5)-methanol (15:85, v/v) and quantified by MS/MS detection in ESI negative ion mode. The flow rate of the mobile phase was 250μl/min and the retention times of FLB, 4'-OH-FLB, and IS were 1.1, 0.8, and 0.9min, respectively. The calibration curves were linear over a range of 0.01-10μg/ml for FLB and 0.01-1μg/ml for 4'-OH-FLB. The lower limit of quantifications using 100μl of human plasma was 0.01μg/ml for both analytes. The mean accuracy and precision for intra- and inter-run validation of FLB and 4'-OH-FLB were all within acceptable limits. The present HPLC-MS/MS method showed improved sensitivity for quantification of the FLB and its major metabolite in human plasma compared with previously described analytical methods. The validated method was successfully applied to a pharmacokinetic study in humans.

Original languageEnglish
Pages (from-to)58-63
Number of pages6
JournalJournal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
Volume971
DOIs
StatePublished - 1 Jan 2014

Keywords

  • 4'-Hydroxyflurbiprofen
  • Flurbiprofen
  • HPLC-MS/MS
  • Human plasma
  • Pharmacokinetics

Fingerprint

Dive into the research topics of 'Simultaneous determination of flurbiprofen and its hydroxy metabolite in human plasma by liquid chromatography-tandem mass spectrometry for clinical application'. Together they form a unique fingerprint.

Cite this