Abstract
This paper discusses the small-signal stability analysis of the combined droop and average power method for load sharing control of multiple distributed generation systems (DGS) in a stand-alone ac supply mode. The small-signal model is developed and its accuracy is verified from simulations of the original nonlinear model. It is shown that the small-signal model accurately predicts the stability of the parallel systems.
| Original language | English |
|---|---|
| Pages (from-to) | 737-745 |
| Number of pages | 9 |
| Journal | IEEE Transactions on Energy Conversion |
| Volume | 22 |
| Issue number | 3 |
| DOIs | |
| State | Published - Sep 2007 |
Keywords
- Distributed generation systems (DGS)
- Parallel operation
- Small-signal model
- Stability analysis
- Stand-alone
- Three-phase pulse width modulation (PWM) inverter