TY - JOUR
T1 - Validation of analytical methods for acrylic acid from various food products
AU - Kim, Yoon Seong
AU - Kim, Yong Yeon
AU - Hwang, Hee Jeong
AU - Shin, Han Seung
N1 - Publisher Copyright:
© 2022, The Korean Society of Food Science and Technology.
PY - 2022/10
Y1 - 2022/10
N2 - Acrylic acid (AA) chemical that endangers human health through contamination of water, soil, and foods. In this study, the extraction, purification, and detection of AA in various food products were established. The contamination level of AA in food products was investigated as well. Food matrices that were used for method validation were crop, fruit, vegetable, seaweed, beverage, sauce, paste, and pickled food, where the validation was confirmed through cross-checking between two different laboratories by checking the accuracy and precision. Furthermore, sample volume for analysis was optimized. Sonication and syringe filtering were all steps preparing headspace analyzer (HA) before GC-MS analysis. Linearity (R2), limit of detection (LOD), limit of quantitation (LOQ), accuracy and precision of AA, were > 0.99, 0.06–0.17 mg/L, 0.18–0.52 mg/L, 90.97–111.93% and 0.12–9.61 RSD% of intra, inter-day, respectively. White rice sample was the only one sample where AA detected (6.19 mg/L) among 102 food samples.
AB - Acrylic acid (AA) chemical that endangers human health through contamination of water, soil, and foods. In this study, the extraction, purification, and detection of AA in various food products were established. The contamination level of AA in food products was investigated as well. Food matrices that were used for method validation were crop, fruit, vegetable, seaweed, beverage, sauce, paste, and pickled food, where the validation was confirmed through cross-checking between two different laboratories by checking the accuracy and precision. Furthermore, sample volume for analysis was optimized. Sonication and syringe filtering were all steps preparing headspace analyzer (HA) before GC-MS analysis. Linearity (R2), limit of detection (LOD), limit of quantitation (LOQ), accuracy and precision of AA, were > 0.99, 0.06–0.17 mg/L, 0.18–0.52 mg/L, 90.97–111.93% and 0.12–9.61 RSD% of intra, inter-day, respectively. White rice sample was the only one sample where AA detected (6.19 mg/L) among 102 food samples.
KW - Acrylic acid
KW - Chemical contaminant
KW - Food
KW - GC-MS
KW - Headspace analyzer
UR - http://www.scopus.com/inward/record.url?scp=85134595939&partnerID=8YFLogxK
U2 - 10.1007/s10068-022-01131-x
DO - 10.1007/s10068-022-01131-x
M3 - Article
AN - SCOPUS:85134595939
SN - 1226-7708
VL - 31
SP - 1377
EP - 1387
JO - Food Science and Biotechnology
JF - Food Science and Biotechnology
IS - 11
ER -