TY - JOUR
T1 - Which Health Impacts of Medical Device Adverse Event Should Be Reported Immediately in Korea?
AU - Choi, Sooin
AU - Choi, Soo Jeong
AU - Kim, Jin Kuk
AU - Yoon, Chiho
AU - Nam, Ki Chang
AU - Kwon, Bum Sun
AU - Lee, You Kyoung
N1 - Publisher Copyright:
© Wolters Kluwer Health, Inc. All rights reserved.
PY - 2022/3/1
Y1 - 2022/3/1
N2 - Objective Immediate medical device adverse event (MDAE) reporting indications of Korea include death, life-threatening, hospitalization (initial or prolonged), disability or permanent damage, and congenital malformation or abnormalities. With the advent of new codes from the International Medical Device Regulators Forum, a study was undertaken to explore the applicability of health impact codes as immediate MDAE reporting indications in the Republic of Korea. Method This domestic cross-sectional survey study was conducted for members from Medical Device Safety Information Monitoring Center in November 2019. For the annex F (health impact) codes defining health impact of an MDAE, we checked whether each code matched with the current indication and asked experts whether they agreed with each code as an indication of immediate reporting. Consensus was reached when ≥70% of experts agreed. Results A total of 28 experts from 19 centers responded to the survey. Of a total of 64 codes, 29 matched with the current indication. However, in an expert survey, 17 of 29 codes were not agreed for immediate reporting and 5 codes were found to be unmatched codes. For these 5 codes, experts agreed that they would need reporting immediately. Finally, only 17 codes achieved consensus for immediate reporting. Conclusions There is a discrepancy between the code matched to the current immediate MDAE reporting indication and experts' consensus. Sufficient discussion and agreement would be needed to apply health impact codes for immediate reporting.
AB - Objective Immediate medical device adverse event (MDAE) reporting indications of Korea include death, life-threatening, hospitalization (initial or prolonged), disability or permanent damage, and congenital malformation or abnormalities. With the advent of new codes from the International Medical Device Regulators Forum, a study was undertaken to explore the applicability of health impact codes as immediate MDAE reporting indications in the Republic of Korea. Method This domestic cross-sectional survey study was conducted for members from Medical Device Safety Information Monitoring Center in November 2019. For the annex F (health impact) codes defining health impact of an MDAE, we checked whether each code matched with the current indication and asked experts whether they agreed with each code as an indication of immediate reporting. Consensus was reached when ≥70% of experts agreed. Results A total of 28 experts from 19 centers responded to the survey. Of a total of 64 codes, 29 matched with the current indication. However, in an expert survey, 17 of 29 codes were not agreed for immediate reporting and 5 codes were found to be unmatched codes. For these 5 codes, experts agreed that they would need reporting immediately. Finally, only 17 codes achieved consensus for immediate reporting. Conclusions There is a discrepancy between the code matched to the current immediate MDAE reporting indication and experts' consensus. Sufficient discussion and agreement would be needed to apply health impact codes for immediate reporting.
KW - medical device adverse event
KW - medical device vigilance
KW - patient safety
KW - regulation
KW - serious adverse event
UR - http://www.scopus.com/inward/record.url?scp=85125008706&partnerID=8YFLogxK
U2 - 10.1097/PTS.0000000000000877
DO - 10.1097/PTS.0000000000000877
M3 - Article
C2 - 34091493
AN - SCOPUS:85125008706
SN - 1549-8417
VL - 18
SP - E591-E595
JO - Journal of Patient Safety
JF - Journal of Patient Safety
IS - 2
ER -